All Categories

Plus et sub intentione protectoris

Pagina Prima >  Producta >  Plus et sub intentione protectoris

tres Fasae 100A Din rail regulabilis Protector contra Superfluentem Subque Tensionem Limitator Currentis Relais SYN ASYNC Synchronus Asynchronus

TOMZN relais Protector Tres Fasi Voltionis et Currentiae 63A 60A 100A 220V 3P+N Relais Voltionis Excessivae et Insufficientis Limitor Currentiae Regolabilis

  • Overview
  • Recommended Products

three phase Tensio Current Relay Protector 63A 60A 100A 220V 3P+N Super Sub Tensio Relay Current limiter regolabilis

ASY+SYN Duo Operatio Modus

Numerus modeli: TOVPD3-100VAS

Tensio nominata: 3*230V

Current: 1-100A

Synchronus (SYN): Three phase Relay Open Close eodem tempore.

Asynchronus (ASY):Three Phase Relay Operari Separatim

1.Over-voltage praesidio: Novifacta

2.Under-voltage praesidio: Novifacta

3.Over-Current praesidio: Adjustable

4. Protectio contra inaequilibrium trifinium

5. Protectio ordinis phasium

6. Tempus activum et tempus reconiunctionis regolabilis

7. Tensio et currentia manualiter calibrari possunt

Codex

Parametrum

Valor

P1

Tempus dilationis post activationem

1-500S

U1

Valor protectii contra voltionem excesivam

230-300V

U2

Valor recuperationis post voltionem excesivam

220-295V

U3

Tempus dilationis recuperationis post voltionem excesivam

1-500S

U4

Tempus actionis protectii contra voltionem excesivam

0.1-30S

U5

Valor protectii contra voltionem infimam

140-210V

U6

Subtensio r tensio Recuperationis

145-215V

U7

Tempus Dalay Recuperationis Subtensionis

1-500S

U8

Tempus Actionis Protectionis Subtensionis

0.1-30S

U9U9

Deviationes Tensionum

-9.5 ad 9.5%

U10

Valorem Triphasicum Inaequilibrium

20-99V

U11

Triphasicum Valorem Imbali Tensionum Recuperationis

15-94V

U12

Tutela sequentiae phasium

ON\/OFF

C1

Valor protectionis contra exsuperantem cursum

1-63A/1-100A/OFF

C2

Tempus tardationis recuperationis cursum exuperantis

1-500S

C3

Tempus actionis tutelae contra cursum potientialem

0.1-30S

C4

Valor erroris currentis

-9.5 ad 9.5%

C5

Permanet Current tempora

1-20/OFF

CEL

Moderatio synchrona vel asynchrona

SAY/SYN

sImg1_2geqqtpd.jpgsImg2_9g3dpxlx.jpgsImg3_yxf87vxz.jpgsImg4_614t6ztg.jpgsImg5_ptyud2v5.jpgsImg6_0ltvl5xp.jpgsImg7_gphhl8t0.jpgsImg8_1hbitavu.jpgsImg9_rdu72gty.jpgsImg10_b7p80iwg.jpgsImg11_vyg9hly5.jpgsImg12_wgp39sk8.jpgsImg13_g0k4gvms.jpgsImg14_7nxxwuyu.jpgsImg15_853qo2kw.jpg

Accipe Citatum Gratuito

Noster legatus cito te continebit.
Email
Nomen
Company Name
Missiva
0/1000